What results from placing the film backward in the patient's mouth?
Show answer and explanation
Correct answer: A herringbone or tire-track pattern
The lead foil backing creates a herringbone pattern. Image density is also reduced.
Practice all 20 Processing Radiographs and Quality Control questions
Keep practicing
More Processing Radiographs and Quality Control questions
- Which of the following indicates fixer exhaustion?
- What happens if films are not adequately washed after fixing?
- Which artifact is caused by bending the film packet?
- What is the purpose of a quality assurance log for radiography?
- Which factor most affects digital radiograph exposure consistency?
- An automatic processor producing films with roller marks requires: