Cardiovascular System Physiology
The cardiovascular system is responsible for circulating blood throughout the body, delivering oxygen and nutrients while removing metabolic waste. This guide covers the heart's anatomy, the cardiac cycle, cardiac output regulation (Frank-Starling mechanism), the electrocardiogram (ECG), blood pressure regulation, hemodynamics, microcirculation, coronary circulation, and cardiac muscle physiology, with reference to Guyton and Hall's Textbook of Medical Physiology.
Heart Anatomy and the Cardiac Cycle
The heart is a four-chambered muscular pump consisting of the right atrium, right ventricle, left atrium, and left ventricle. The right side receives deoxygenated blood and pumps it to the lungs; the left side receives oxygenated blood from the lungs and pumps it to the body. Four valves ensure unidirectional blood flow: the tricuspid valve (right AV), mitral or bicuspid valve (left AV), pulmonary valve, and aortic valve.
The cardiac cycle consists of alternating periods of contraction (systole) and relaxation (diastole). Four mechanical phases occur during each cycle: (1) ventricular filling, where blood flows from the atria into the ventricles (rapid filling followed by atrial contraction or 'atrial kick'), (2) isovolumetric contraction, where all valves are closed and ventricular pressure rises without a change in volume, (3) ejection, where the semilunar valves open and blood is ejected into the aorta and pulmonary artery, and (4) isovolumetric relaxation, where all valves are again closed and ventricular pressure falls. The first heart sound (S1) is produced by closure of the AV valves at the start of systole, and the second heart sound (S2) by closure of the semilunar valves at the end of systole.
- End-diastolic volume (EDV): the volume of blood in the ventricle at the end of filling, normally about 120 mL.
- End-systolic volume (ESV): the volume remaining after ejection, normally about 50 mL.
- Stroke volume (SV) = EDV minus ESV, normally about 70 mL.
- Ejection fraction (EF) = SV divided by EDV, normally about 55-70%.
Cardiac Output and Its Regulation
Cardiac output (CO) is the volume of blood pumped by each ventricle per minute, calculated as heart rate (HR) multiplied by stroke volume (SV). The normal resting cardiac output is approximately 5 liters per minute. Three factors determine stroke volume: preload (the degree of ventricular stretch at end-diastole, mainly determined by venous return), afterload (the resistance the ventricle must overcome to eject blood, approximated by arterial pressure), and contractility (the intrinsic strength of cardiac muscle contraction independent of preload and afterload).
The Frank-Starling law (or Starling's law of the heart) states that within physiological limits, the greater the venous return and end-diastolic volume, the greater the stretch of cardiac muscle fibers, and the more forceful the subsequent contraction. This intrinsic mechanism allows the heart to automatically match its output to the volume of blood returning to it, without requiring neural or hormonal input.
- Increased preload (venous return) increases stroke volume via the Frank-Starling mechanism.
- Increased afterload (arterial resistance) decreases stroke volume because the ventricle must work harder to eject blood.
- Increased contractility (positive inotropic effect) increases stroke volume; sympathetic stimulation and catecholamines increase contractility.
- Heart rate is regulated by the autonomic nervous system: sympathetic stimulation increases heart rate; parasympathetic (vagal) stimulation decreases heart rate.
Electrocardiogram and Arrhythmias
The electrocardiogram (ECG) is a recording of the electrical activity of the heart from the body surface. The normal ECG shows the P wave (atrial depolarization), QRS complex (ventricular depolarization), and T wave (ventricular repolarization). The PR interval (from the start of the P wave to the start of the QRS) represents conduction through the AV node and is normally 0.12 to 0.20 seconds. The QT interval (from the start of QRS to the end of the T wave) represents total ventricular depolarization and repolarization time.
Common arrhythmias include: atrial fibrillation (chaotic, disorganized atrial electrical activity with an irregularly irregular ventricular response and absence of discrete P waves), ventricular fibrillation (chaotic ventricular electrical activity producing no effective cardiac output, a medical emergency requiring immediate defibrillation), and heart blocks. First-degree AV block shows a prolonged PR interval (greater than 0.20 seconds). Second-degree AV block involves intermittent failure of conduction from atria to ventricles. Third-degree (complete) heart block shows complete AV dissociation where the atria and ventricles beat independently.
- The SA node is the normal pacemaker of the heart with an intrinsic rate of approximately 70-80 beats per minute.
- The AV node introduces a delay (reflected in the PR interval) to allow atrial contraction to finish before ventricular contraction begins.
- Atrial fibrillation is the most common sustained cardiac arrhythmia.
- Ventricular fibrillation is rapidly fatal without defibrillation because the heart cannot effectively pump blood.
Blood Pressure Regulation and Hemodynamics
Blood pressure is regulated by both short-term and long-term mechanisms. The baroreceptor reflex is a rapid, neural mechanism: stretch receptors in the carotid sinus and aortic arch detect changes in arterial pressure. When blood pressure rises, increased baroreceptor firing leads to decreased sympathetic outflow and increased parasympathetic activity, lowering heart rate and causing vasodilation. The renin-angiotensin-aldosterone system (RAAS) provides longer-term regulation: decreased renal perfusion stimulates renin release, which converts angiotensinogen to angiotensin I, then angiotensin-converting enzyme (ACE) converts it to angiotensin II, a potent vasoconstrictor that also stimulates aldosterone release for sodium and water retention. Atrial natriuretic peptide (ANP) is released by stretched atria and promotes sodium and water excretion, opposing RAAS. Normal blood pressure is approximately 120/80 mmHg.
Blood flow is governed by the relationship: flow equals the pressure difference divided by resistance. Poiseuille's law states that flow is proportional to the fourth power of the vessel radius, meaning small changes in vessel radius have a dramatic effect on flow and resistance. Arterioles are the primary resistance vessels and the main regulators of blood flow distribution and total peripheral resistance.
- Doubling the vessel radius increases blood flow 16-fold (2 to the 4th power).
- Total peripheral resistance (TPR) is the sum of resistances across the entire systemic vascular bed.
- Mean arterial pressure (MAP) is approximately equal to diastolic pressure plus one-third of pulse pressure.
- The baroreceptor reflex is a short-term mechanism that resets over days and cannot maintain long-term blood pressure control alone.
Microcirculation, Coronary Circulation, and Cardiac Muscle
At the capillary level, fluid exchange between blood and tissues is governed by Starling forces. Capillary hydrostatic pressure and interstitial oncotic pressure favor filtration (fluid moving out of the capillary), while plasma oncotic (colloid osmotic) pressure and interstitial hydrostatic pressure favor reabsorption (fluid moving into the capillary). Net filtration predominates at the arteriolar end, while net reabsorption occurs at the venular end. The lymphatic system returns excess filtered fluid and escaped proteins to the venous circulation, preventing edema.
Coronary blood flow is unique because the left coronary artery (which supplies most of the left ventricle via the LAD and circumflex branches) receives approximately 75% of its flow during diastole. This occurs because systolic contraction of the thick left ventricular wall compresses the intramural vessels, impeding flow during systole. Tachycardia (rapid heart rate) shortens diastole and can compromise coronary perfusion. Cardiac muscle has a long refractory period due to a prolonged action potential plateau phase, which prevents tetanic contraction and ensures the heart relaxes between beats. Cardiac cells are connected by intercalated discs containing gap junctions that allow rapid electrical conduction, making the heart function as a coordinated syncytium.
- Edema results when filtration exceeds the combined rate of reabsorption and lymphatic drainage.
- The SA node's automaticity (self-depolarization) makes it the heart's primary pacemaker.
- Gap junctions in intercalated discs allow the action potential to spread rapidly from cell to cell.
- The long cardiac refractory period prevents summation and tetanus, unlike skeletal muscle.
Key Terms
- Frank-Starling Law
- The principle that the force of cardiac contraction is proportional to the initial length (stretch) of the cardiac muscle fiber, allowing the heart to automatically adjust its output to match the volume of venous return.
- Cardiac Output
- The volume of blood pumped by each ventricle per minute, calculated as heart rate multiplied by stroke volume. Normal resting value is approximately 5 liters per minute.
- Baroreceptor Reflex
- A rapid negative-feedback mechanism in which stretch receptors in the carotid sinus and aortic arch detect changes in blood pressure and adjust heart rate and vascular tone through the autonomic nervous system.
- Afterload
- The resistance or pressure that the ventricle must overcome to eject blood during systole, primarily determined by arterial blood pressure and total peripheral resistance.
Practice Quiz
-
Question 1 of 20
Cardiac output is calculated as:
- ABlood pressure multiplied by resistance
- BHeart rate multiplied by stroke volume
- CEnd-diastolic volume minus end-systolic volume
- DMean arterial pressure divided by heart rate
B. Heart rate multiplied by stroke volume — Cardiac output = heart rate x stroke volume. Normal resting CO is about 5 L/min (72 bpm x 70 mL). -
Question 2 of 20
Normal resting cardiac output is approximately:
- A2 L/min
- B5 L/min
- C10 L/min
- D15 L/min
B. 5 L/min — Normal resting cardiac output is about 5 liters per minute, as stated in Guyton and Hall. -
Question 3 of 20
The Frank-Starling law states that:
- AHeart rate determines blood pressure
- BIncreased venous return leads to increased stroke volume
- CAfterload has no effect on cardiac output
- DThe heart cannot adapt to changes in blood volume
B. Increased venous return leads to increased stroke volume — The Frank-Starling law describes how increased venous return stretches cardiac muscle fibers, leading to a more forceful contraction and greater stroke volume. -
Question 4 of 20
The first heart sound (S1) is produced by closure of the:
- AAortic and pulmonary valves
- BTricuspid and mitral valves
- CPulmonary valve only
- DAortic valve only
B. Tricuspid and mitral valves — S1 is produced by closure of the atrioventricular valves (tricuspid and mitral) at the beginning of ventricular systole. -
Question 5 of 20
During isovolumetric contraction:
- ABlood is ejected into the aorta
- BAll heart valves are closed
- CThe atria are contracting
- DBlood fills the ventricles
B. All heart valves are closed — During isovolumetric contraction, all four valves are closed. Ventricular pressure rises but volume does not change because no blood enters or leaves. -
Question 6 of 20
The P wave on an ECG represents:
- AVentricular depolarization
- BAtrial depolarization
- CVentricular repolarization
- DAtrial repolarization
B. Atrial depolarization — The P wave represents the spread of electrical depolarization through the atria. -
Question 7 of 20
The QRS complex represents:
- AAtrial depolarization
- BAtrial repolarization
- CVentricular depolarization
- DVentricular repolarization
C. Ventricular depolarization — The QRS complex represents the electrical depolarization of the ventricles, which triggers ventricular contraction. -
Question 8 of 20
A prolonged PR interval (greater than 0.20 seconds) indicates:
- AAtrial fibrillation
- BFirst-degree AV block
- CVentricular fibrillation
- DBundle branch block
B. First-degree AV block — A PR interval greater than 200 ms indicates delayed conduction through the AV node, defined as first-degree AV block. -
Question 9 of 20
Ventricular fibrillation is life-threatening because:
- AThe heart beats too slowly
- BThe ventricles cannot pump blood effectively
- CBlood pressure rises dangerously
- DThe atria stop contracting
B. The ventricles cannot pump blood effectively — In ventricular fibrillation, the ventricles quiver chaotically instead of contracting in a coordinated manner, so no effective blood is pumped. -
Question 10 of 20
The normal pacemaker of the heart is the:
- AAV node
- BBundle of His
- CSA node
- DPurkinje fibers
C. SA node — The SA (sinoatrial) node has the highest intrinsic rate of depolarization (70-80 bpm) and sets the pace for the entire heart. -
Question 11 of 20
Baroreceptors that detect arterial blood pressure are located in the:
- ARight atrium and ventricle
- BCarotid sinus and aortic arch
- CCoronary arteries
- DPulmonary veins
B. Carotid sinus and aortic arch — Baroreceptors are stretch receptors located in the carotid sinus and aortic arch that monitor arterial blood pressure. -
Question 12 of 20
In the renin-angiotensin-aldosterone system, angiotensin II causes:
- AVasodilation and sodium excretion
- BVasoconstriction and aldosterone release
- CDecreased blood volume
- DDecreased heart rate
B. Vasoconstriction and aldosterone release — Angiotensin II is a potent vasoconstrictor and stimulates aldosterone secretion from the adrenal cortex, promoting sodium and water retention to raise blood pressure. -
Question 13 of 20
Atrial natriuretic peptide (ANP) is released in response to:
- ALow blood pressure
- BDehydration
- CAtrial stretching due to increased blood volume
- DSympathetic stimulation
C. Atrial stretching due to increased blood volume — ANP is released from stretched atrial cardiomyocytes when blood volume (and therefore atrial pressure) is high, promoting natriuresis and diuresis to lower blood volume. -
Question 14 of 20
According to Poiseuille's law, if the radius of a vessel is doubled, flow increases by:
- A2 times
- B4 times
- C8 times
- D16 times
D. 16 times — Flow is proportional to the fourth power of the radius. Doubling the radius increases flow by 2 to the 4th power = 16 times. -
Question 15 of 20
The primary resistance vessels in the circulation are the:
- AVeins
- BCapillaries
- CArterioles
- DVenules
C. Arterioles — Arterioles have thick smooth muscle walls relative to their lumen size and are the major site of resistance regulation in the vascular system. -
Question 16 of 20
Left coronary artery blood flow is greatest during:
- AVentricular systole
- BVentricular diastole
- CAtrial systole
- DIsovolumetric contraction
B. Ventricular diastole — About 75% of left coronary flow occurs during diastole because systolic contraction of the thick left ventricular wall compresses the coronary vessels. -
Question 17 of 20
Cardiac muscle cannot undergo tetanic contraction because of its:
- AShort refractory period
- BLong refractory period
- CLack of calcium channels
- DAbsence of gap junctions
B. Long refractory period — The long refractory period of cardiac muscle (due to the prolonged action potential plateau) ensures the muscle relaxes fully between contractions, preventing tetanus. -
Question 18 of 20
Intercalated discs in cardiac muscle contain gap junctions that:
- APrevent electrical conduction
- BAllow rapid electrical conduction between cells
- CStore calcium ions
- DProduce ATP
B. Allow rapid electrical conduction between cells — Gap junctions provide low-resistance electrical coupling between adjacent cardiac myocytes, allowing the action potential to spread rapidly so the heart contracts as a coordinated unit. -
Question 19 of 20
Net filtration at the capillary level is primarily driven by:
- APlasma oncotic pressure
- BCapillary hydrostatic pressure
- CInterstitial hydrostatic pressure
- DVenous pressure
B. Capillary hydrostatic pressure — Capillary hydrostatic pressure (the blood pressure within the capillary) is the main force pushing fluid out of the capillary into the interstitial space. -
Question 20 of 20
Preload is best defined as:
- AThe pressure the ventricle must overcome to eject blood
- BThe degree of ventricular stretch at end-diastole
- CThe force of cardiac contraction
- DThe rate of blood flow through the coronary arteries
B. The degree of ventricular stretch at end-diastole — Preload refers to the stretch of ventricular muscle fibers at end-diastole, primarily determined by venous return and end-diastolic volume.
References
- Guyton and Hall Textbook of Medical Physiology, 14th Edition — https://www.elsevier.com/books/guyton-and-hall-textbook-of-medical-physiology/hall/978-0-323-59712-8
- CV Physiology - Cardiovascular Physiology Concepts — https://cvphysiology.com/
- Khan Academy - Circulatory System — https://www.khanacademy.org/science/health-and-medicine/circulatory-system
- StatPearls - Physiology, Cardiac Cycle (NCBI Bookshelf) — https://www.ncbi.nlm.nih.gov/books/NBK459327/